Transmission rate | ||
Transfer rate | ||
● at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s | |
Interfaces | ||
Number of electrical connections | ||
● at the 1st interface / acc. to PROFIBUS | 1 | |
Type of electrical connection | ||
● at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS 485) | |
Supply voltage, current consumption, power loss | ||
Type of voltage / of the supply voltage | DC | |
Supply voltage | ||
● 1 / from backplane bus | 3.3 V | |
● 2 / from backplane bus | 12 V | |
Relative symmetrical tolerance / at DC | ||
● at 3.3 V | 9 % | |
● at 12 V | 8 % | |
Consumed current | ||
● 1 / from backplane bus / at DC / maximum | 0.4 A | |
● 2 / from backplane bus / at DC / maximum | 0.18 A | |
Power loss [W] | 2.2 W | |
Permitted ambient conditions | ||
Ambient temperature | ||
● during operation | 5 ... 55 °C | |
● during storage | -20 ... +60 °C | |
● during transport | -20 ... +60 °C | |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 85 % | |
Protection class IP | IP00 | |
Design, dimensions and weight | ||
Module format | PCI Express x1 | |
Width | 18 mm | |
Height | 111 mm | |
Depth | 129 mm | |
Net weight | 100 g | |
Number of plug-in cards of same design / plug-in / per PC station | 1 | |
Number of units / Note | FMS-5613 supports up to two CP 5603 / CP 5613 A2 / CP 5614 A2 / CP 5623 / CP 5624 processors | |
Performance data | ||
Performance data / open communication | ||
Software / for open communication / by means of SEND/RECEIVE / required | Yes, SOFTNET-PB DP / SOFTNET-PB DP Slave / SOFTNET-PB S7 | |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum | 50 | |
Performance data / PROFIBUS DP | ||
Software / for DP master function / required | Yes, SOFTNET-PB DP | |
Service / as DP master | ||
● DPV0 | Yes | |
● DPV1 | Yes | |
● DPV2 | No | |
Number of DP slaves / on DP master / usable | 64 | |
Amount of data | ||
● of the address area of the inputs / as DP master / total | 14640 byte | |
● of the address area of the outputs / as DP master / total | 14640 byte | |
● of the address area of the inputs / per DP slave | 244 byte | |
● of the address area of the outputs / per DP slave | 244 byte | |
● of the address area of the diagnostic data / per DP slave | 244 byte | |
Software / for DP slave function / required | Yes, SOFTNET-PB DP slave | |
Service / as DP slave | ||
● DPV0 | Yes | |
● DPV1 | No | |
Amount of data | ||
● of the address area of the inputs / as DP slave / total | 122 byte | |
● of the address area of the outputs / as DP slave / total | 122 byte | |
Performance data / S7 communication | ||
Software / for S7 communication / required | Yes, SOFTNET-PB S7 | |
Number of possible connections / for S7/PG communication / maximum | 8 | |
Performance data / multi-protocol mode | ||
Number of configurable connections / per PC station | 207 | |
Product functions / management, configuration | ||
Configuration software / required | Included in the scope of delivery of the required software product | |
Product functions / Diagnosis | ||
Product function | ||
● Port diagnostics | Yes | |
Standards, specifications, approvals | ||
Standard | ||
● for EMC | 2004/108/EC | |
● for safety / from CSA and UL | CAN/CSA C22.2 & UL 60950-1, UL 508 | |
● for emitted interference | EN 61000-6-3, EN 61000-6-4 | |
● for interference immunity | EN 61000-6-1, EN 61000-6-2 | |
Certificate of suitability | ||
● CE marking | Yes | |
● C-Tick | Yes |